Multifunctional system LLW/HHW

discontinuous waterlevel controlling
(2-point)

Application and function

  • Supply or drain control
  • LW or HW Signalling
  • Functional with either 2 to 3 single-rod-probes or 1 multi-rod-probe (3 rods)
  • programmable evaluator DCU
  • PS = 32 bar / 464 psi with single-rod probes (DP311 + DCU), or with a 3-rod-probe (DP313 + DCU)
  • PS = 200 bar / 2901 psi with single-rod probes (DP321 + DCU)